25000MC1 Type 2
25000MC1| Type 1
Technical Specification
Overall dimensions …………………………….. 2260 mm × 1010 mm
Mattress platform ………………………………. 2000 mm × 810 mm
Height ……………………………………………….. 570 mm
Side rail height …………………………………… 410 mm
Side rail length …………………………………… 1620 mm
Backrest angle …………………………………… 0 – 70º
Knee rest angle ………………………………….. 0 – 35º
Bed weight ………………………………………… 98 kg
Safe working load ………………………………. 250 kg
Casters ……………………………………………… 125mm
Technical and Quality Assurance Standards
IEC 60601-2-52
ISO 13485
ISO 14971
25000MC1| Type 1
Featuers
Head & Foot Boards
The seamless blow molded bed ends of 25000MC1 are lightweight, durable, and easy to clean. The bed ends are of high quality and compatible for steam cleaning. In order to have better access to the patient’s head in emergency cases, the caregiver can easily remove the bed ends by grasping the hand holds and lifting them up in one single step. Moreover, the bed ends have integrated steel fittings which make them extremely rigid; so the nursing staff can move the bed by holding and pushing them without worries.
Foldable Cranks
Back and knee positions can be adjusted by two foldable cranks located at foot end of the bed.
Side Rails
The parallel side rails of the 22000MC1 offer a unique and stylish design produced from a combination of blow molded plastic and steel bars to provide a protective height and length. The side rails adhere to the highest standards of safety to prevent patient falls and entrapment.
Urine Bag Holder
Urine bag holders can be easily installed on either side of the bed in one step.
25000MC1| Type 1
Mattress Platforms
The ABS mattress platforms of this general bed are produced by injection molding method. These platforms have some remarkable features such as smooth surfaces, high durability, and easy to remove for cleaning and disinfection. Plus, the mattress platforms are compatible for steam cleaning.
Casters
125 mm casters run extremely smoothly; the quality that makes it significantly easy for the nursing staff to transport the bed in the medical centres. Having diagonal locks, the casters can be locked in order to prevent the bed from unintended movement.
Bumpers
Rotary bumpers which are located on four corners of 25000MC1 can prevent to a large extent the damages that may occur due to unwanted collision of the bed to the surroundings during transportation.
Urine Bag Holder
Urine bag holders can be easily installed on either side of the bed in one step.
25000MC1| Type 1
Positions
| Backrest |
| Kneerest |
| Fowler |